Contact SoundGT

Ground Source
Heat Pump
Technology

Economics of a
Geothermal Heat
Pump

Operating Cost
Estimator

Energy Recovery
Ventilation"ERV"
and
Heat Recovery
Ventilation"HRV"

Practical GeoExchange Applications

School 2004
IGSHPA
Certification
and Workshops

Other Sites and
More Information
about
Water Source
Heat Pumps

Key Personnel

Dealerships

SoundGT.com
Home

 


sound geothermal heat


An Important Renewable Energy Technology EV-130
An Important Renewable Energy Technology
EV-200
An Important Renewable Energy Technology EV-300
An Important Renewable Energy Technology How Energy Recovery Ventilators Work
An Important Renewable Energy Technology Installation
An Important Renewable Energy Technology Download Manuals

An Important Renewable Energy Technology Sizing Calculator
An Important Renewable Energy Technology How to buy online

 

For small houses, apartments
                                           and townhouses


An Important Renewable Energy Technology
About Breeze
An Important Renewable Energy Technology
Schematics
An Important Renewable Energy Technology
Installation/Operation Manual
An Important Renewable Energy Technology Thru-the-Wall Installation Manual
An Important Renewable Energy Technology Breeze - More Information


EV-130 is a ducted, whole-house energy recovery ventilator sized to provide general ventilation in most homes. The EV-130 is ideal for any home with up to 2,350 square feet of living area. The EV-130 has a rated temperature effectiveness of seventy-nine percent.110 CFM.

EV-130

 

EV-200 is a ducted, whole-house energy recovery ventilator sized to provide general ventilation in most homes. The EV-200 is ideal for any home with up to 4,500 square feet of living area. The EV-200 has a rated temperature effectiveness of seventy-nine percent. 210 CFM.

ENERGY RECOVERY VENTILATOR, VENTILATION TO HOMESEV-200

 

EV-300 EnergyExchange System: Cross flow fixed-plate enthalpic heat exchanger core; engineered, proprietary resin-ediacomposite. Provides both sensible and latent heat transfer.  Airflow Range: 150-320 CFM each air stream.  Rated Airflow: 300 CFM for each air stream at 0.4" external static pressure (ESP).  Certified Performance: HVI certification pending, see ARI Certification Report (L100core).  Dimension: 28 3/4" wide x 20 1/8" high x 24" deep (Not including duct collars). Unit Weight: 86 lbs. Access Cover: Front panel opens to provide access to filters, blowers, and heat exchanger. Snap latches and hinges provided for easy service.  Insulation: One inch foil-faced fiberglass throughout. Additional 1/4" foam insulation on access panel for thermal and sound insulation.  Duct Connections: Eight inch oval connections for flexible or rigid duct work.  Mounting Options: Unit maybe mounted to wall or floor joists using integral mounting flange with hanging bracket kit provided.  Blower/Motor: A single high efficiency PSC motor directly drives two large diameter centrifugal blowers for quiet operation.  Electrical: Power: 0.2HP, 115Volt, 60Cycle, single phase, 3.3amps, 300 watts at 300 CFM. Control: 24volt, transformer and relay provided. Line voltage control also possible.  Filters: Cleanable polyester air filters for both exhaust and fresh air streams.  Defrost: Passive frost-free design under most residential conditions. Optional defrost accessory available for severe applications and climate zones.  Warranty: Ten year limited warranty on heat exchange core; two year limited warranty against defects in material and workmanship on all other components.

          EV-300

 

NOTE: Larger commercial units are available.   Please contact us for more information: info@soundgt.com

TOP


Contact SoundGT

Ground Source
Heat Pump
Technology

Economics of a
Geothermal Heat
Pump

Operating Cost
Estimator

Energy Recovery
Ventilation"ERV"
and
Heat Recovery
Ventilation"HRV"

Practical GeoExchange Applications

School 2004
IGSHPA
Certification
and Workshops

Other Sites and
More Information
about
Water Source
Heat Pumps

Key Personnel

Dealerships

SoundGT.com
Home

How Energy Recovery Ventilators Work:

In the RenewAire (formerly Lossnay) energy exchange core, the exhausted stale air and the fresh ventilation air pass through multiple air passages separated by an engineered composite resin partition plate. Sensible heat transfers from the warmer to the cooler air stream. Also, latent energy (water vapor in the gas state) transfers from the wetter to the drier air stream. The fresh incoming air is automatically preheated or precooled depending on the season. This dramatically reduces the energy costs of ventilation.

This unique moisture transfer feature of the RenewAire (formerly Lossnay) energy exchange core eliminates condensate and frosting in most applications. No mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, simpler installation and more reliable operation.


During the Heating Season:

Outdoor air is warmed to close-to-room temperature with heat that would otherwise be lost with the exhaust air. Indoor humidity levels are prevented from becoming too dry or too humid by the partial transfer of water vapor. Non-enthalpic heat recovery systems cannot deliver that benefit.

 

 

During the Air Conditioning Season:

RenewAire (formerly Lossnay) Core systems recover coolness and dryness from the exhausted air. Outside air brought in for ventilation is reduced in temperature and humidity because its heat and humidity is transferred to the exhaust air stream.

With summer-time humidity (latent load) being the largest portion of the cooling load associated with outside air ventilation, this humidity transfer is critical. Other plate-type heat exchangers can’t touch this major load. RenewAire (formerly Lossnay) makes it easier for your air conditioning system to keep you both cool and dry.

LOSSNAY CORE TRANSFERS ENERGY

INSTALLATIONS,  SIZES, AND SAVINGS - Click Here